In the case of continuous ventilation, subglottic secretions can be aspirated.
Connecting the sputum suction tube to the automatic sputum suction device can realize regular sputum suction, improve the safety of critical disease management and reduce the work intensity of medical workers.
The pressure indicator can monitor the pressure of cuff in real time.
The cuff is made of PU, and the thickness can be as thin as 0.04mm. High volume and low pressure cuff improves the fit with the airway,
The tightness is better under the same pressure. Reduce the friction with mucosa, so as to reduce the damage to airway.
Guide wire can be selected according to demand
High strength steel wire is embedded to improve the anti twist and bending performance of the pipe body.
Nominal specification: 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10.0
Applicable departments: anesthesia department, respiratory department, emergency department and ICU
In the case of continuous ventilation, subglottic secretions can be aspirated.
Connecting the sputum suction tube to the automatic sputum suction device can realize regular sputum suction, improve the safety of critical disease management and reduce the work intensity of medical workers.
The pressure indicator can monitor the pressure of cuff in real time.
The cuff is made of PU, and the thickness can be as thin as 0.04mm. High volume and low pressure cuff improves the fit with the airway,
The tightness is better under the same pressure. Reduce the friction with mucosa, so as to reduce the damage to airway.
Guide wire can be selected according to demand
High strength steel wire is embedded to improve the anti twist and bending performance of the pipe body.
Nominal specification: 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10.0
Applicable departments: anesthesia department, respiratory department, emergency department and ICU
In the case of continuous ventilation, subglottic secretions can be aspirated.
Connecting the sputum suction tube to the automatic sputum suction device can realize regular sputum suction, improve the safety of critical disease management and reduce the work intensity of medical workers.
The pressure indicator can monitor the pressure of cuff in real time.
The cuff is made of PU, and the thickness can be as thin as 0.04mm. High volume and low pressure cuff improves the fit with the airway,
The tightness is better under the same pressure. Reduce the friction with mucosa, so as to reduce the damage to airway.
Guide wire can be selected according to demand
High strength steel wire is embedded to improve the anti twist and bending performance of the pipe body.
Nominal specification: 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10.0
Applicable departments: anesthesia department, respiratory department, emergency department and ICU
Matters needing attention
1. This product does not contain DEHP;
2. The product has been sterilized by ethylene oxide and is valid for 3 years from the date of sterilization;
3. One-time use, please destroy after use;
4. Must be used by professionals;
5. Extubation must be performed when the patient can breathe autonomously and is awake;
6. Check whether the cuff is leaking before use. Pay attention to the amount of inflation during the inflation test and intraoperative inflation, so as to avoid excessive inflation and damage of the cuff;
7. Keep away from fire or heat sources to avoid fire or heat deformation of instruments.

Copy product links