Dual visual design, the whole process of laryngeal mask placement can be seen, and the fitting state around the mask capsule can be accurately observed to ensure that the glottis is completely exposed; And the pressure indicator can monitor the pressure of the hood throughout the whole process, real-time monitoring of reflux, reduce aspiration; Laryngeal mask capsule is made of silicone material, soft and comfortable, good sealing; Embedded high-strength steel wire, improve the anti-distortion and anti-bending performance of the tube body, free the time limit and position limit of the laryngeal mask, especially suitable for head and face surgery; Instant alignment, less damage, reduce damage caused by visual field defects or blind exploration; Size: 1.0#, 1.5#, 2.0#, 2.5#, 3.0#, 4.0#, 5.0#, 6.0#
Dual visual design, the whole process of laryngeal mask placement can be seen, and the fitting state around the mask capsule can be accurately observed to ensure that the glottis is completely exposed; And the pressure indicator can monitor the pressure of the hood throughout the whole process, real-time monitoring of reflux, reduce aspiration; Laryngeal mask capsule is made of silicone material, soft and comfortable, good sealing; Embedded high-strength steel wire, improve the anti-distortion and anti-bending performance of the tube body, free the time limit and position limit of the laryngeal mask, especially suitable for head and face surgery; Instant alignment, less damage, reduce damage caused by visual field defects or blind exploration; Size: 1.0#, 1.5#, 2.0#, 2.5#, 3.0#, 4.0#, 5.0#, 6.0#
Matters needing attention
1. This product is sterilized by ethylene oxide and is a sterile product.
2. This product is a disposable product. If the packaging is damaged, it is forbidden to use it. After use, it should be completely scrapped and cannot be used again.
3. If you have allergies, please contact the doctor in time.
4. Select relevant models and specifications according to clinical needs.
5. The sac, indicator bag or pressure indicator must be inflated and deflated before use. Do not use this product when the casing is broken, the indicator bag, the pressure indicator has any air leakage.
6. The medical device belongs to the mucous membrane contact medical device in contact with the human surface, and the main components that contact the human body are the capsule and ventilation tube. The specific insertion time is subject to the doctor's instructions, and it is recommended that the continuous use time should not exceed 24 hours.
7. This product is only used for connecting dedicated tablet devices, not for connecting other devices. This product is not to be used in conjunction with other electric treatment devices.
8. This product should not be used in oxygen-rich environment.
9. Requirements for tablets used together:
(a) The safety requirements for tablet computers shall comply with GB 9706.1-2020 Medical Electrical Equipment - Part 1: General requirements for Essential safety and Essential Performance.
(b) When the tablet is powered as an internal power supply, the voltage supplied is 5V and the current is 50mA.
(c) The tablet may not be connected to the Product while charging, and may only be connected to the product when powered by an internal power source.
(d) After the tablet is connected to the Product, it cannot be connected to other devices through other interfaces.
(e) For information on the operation and maintenance of the tablet, please refer to the user manual of the tablet.


Copy product links
Long by picture save/share